The short answer. Run the old and new models against both the old and new retrieved evidence for the same frozen cases. Keep the prompt, response contract and scoring rule fixed. Inspect the model-only change, the retrieval-only change and what happens when the changes meet. The comparison can show that a combined configuration causes the observed loss under that fixture.
In a release that updates the model and reindexes the knowledge base, comparing production against the combined candidate can reveal a regression without identifying where it arose. That matters when you have to choose whether to restore the model, restore the retrieval configuration, or fix an interaction before promoting either.
Preserve four reproducible conditions
Store the authorized retrieved passages, their identifiers and order, and the input revision for every case. Replay those passages to both model revisions. Pin the prompt text and settings, final context budget and output checks. If a model-specific rendering difference cannot be eliminated, describe it as part of the model treatment. Grade citations against the specific supplied context and compare final task judgments to the same reference.
Use a stable case set and record missing completions before interpreting scores. Start with a small representative set and include the reported failure mode. Where generation is stochastic, repeat the crossed comparisons enough to assess run-to-run differences under your constraints. Include a baseline replay to catch a shared break in the fixture before blaming one changed component.
Read a synthetic four-cell result
All cells below use the same 100 cases. A pass means all required evidence is covered and the answer contains no unsupported material claim.
| Model revision | Old retrieved evidence | New retrieved evidence |
|---|---|---|
| Old model | 90 / 100 | 86 / 100 |
| New model | 91 / 100 | 76 / 100 |
On old evidence, replacing the model improves the aggregate by one percentage point. On new evidence, replacing the model reduces it by ten points. The difference between those two model effects is minus eleven points. The combined candidate is also fourteen points below the old baseline. These observed differences are descriptive. Review which matched cases changed and how much of the difference persists across repeats before drawing a broader conclusion.
The NIST engineering statistics handbook on two-level factorial designs describes crossing factor levels. Here, freezing the actual passages makes the two interventions inspectable in the context of a RAG application.
Follow changed cases to a reversible decision
Look for cases where both factors change together and compare source spans, the assembler's final context and the answer's claimed evidence. An illustrative cause could be that the new index supplies the qualifier later in a long passage and the new model misses it under that presentation. That is a hypothesis. A follow-up with the same evidence reordered can challenge it while the remaining factors stay fixed.
Record which cases pass in one cell and fail in the paired cell, including completions missing in either condition. Aggregate cell scores can hide offsetting gains and losses. Review the failures that changed at the release threshold before deciding which factor to restore.
If the old evidence projection keeps the model-only candidate inside the release rule, that cell is eligible for further verification on its own. Retain the combined result as a failed condition on this fixture and use fresh cases for the repaired configuration. sinc-LLM’s paired shadow evaluation guide explains how to preserve matched live requests for a later check.
sinc-LLM